<?xml version="1.0"?>
<feed xmlns="http://www.w3.org/2005/Atom" xml:lang="en">
	<id>https://ohcnwiki.tellmey.fyi/index.php?action=history&amp;feed=atom&amp;title=TELEICU%2FPower_loss_runbook</id>
	<title>TELEICU/Power loss runbook - Revision history</title>
	<link rel="self" type="application/atom+xml" href="https://ohcnwiki.tellmey.fyi/index.php?action=history&amp;feed=atom&amp;title=TELEICU%2FPower_loss_runbook"/>
	<link rel="alternate" type="text/html" href="https://ohcnwiki.tellmey.fyi/index.php?title=TELEICU/Power_loss_runbook&amp;action=history"/>
	<updated>2026-07-06T07:15:09Z</updated>
	<subtitle>Revision history for this page on the wiki</subtitle>
	<generator>MediaWiki 1.45.4</generator>
	<entry>
		<id>https://ohcnwiki.tellmey.fyi/index.php?title=TELEICU/Power_loss_runbook&amp;diff=289&amp;oldid=prev</id>
		<title>Admin: Automated edit (via update-page on MediaWiki MCP Server)</title>
		<link rel="alternate" type="text/html" href="https://ohcnwiki.tellmey.fyi/index.php?title=TELEICU/Power_loss_runbook&amp;diff=289&amp;oldid=prev"/>
		<updated>2026-07-06T03:10:12Z</updated>

		<summary type="html">&lt;p&gt;Automated edit (via update-page on MediaWiki MCP Server)&lt;/p&gt;
&lt;table style=&quot;background-color: #fff; color: #202122;&quot; data-mw=&quot;interface&quot;&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;col class=&quot;diff-marker&quot; /&gt;
				&lt;col class=&quot;diff-content&quot; /&gt;
				&lt;tr class=&quot;diff-title&quot; lang=&quot;en&quot;&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;← Older revision&lt;/td&gt;
				&lt;td colspan=&quot;2&quot; style=&quot;background-color: #fff; color: #202122; text-align: center;&quot;&gt;Revision as of 08:40, 6 July 2026&lt;/td&gt;
				&lt;/tr&gt;&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 47:&lt;/td&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-lineno&quot;&gt;Line 47:&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Consider solar + battery for high-priority sites with frequent power loss&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Consider solar + battery for high-priority sites with frequent power loss&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Graceful shutdown scripts on UPS trigger can be added via ansible or NixOS module&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;* Graceful shutdown scripts on UPS trigger can be added via ansible or NixOS module&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td colspan=&quot;2&quot; class=&quot;diff-empty diff-side-deleted&quot;&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot; data-marker=&quot;+&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #a3d3ff; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;{{Navbox TELEICU}}&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;br /&gt;&lt;/td&gt;
&lt;/tr&gt;
&lt;tr&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;{{Related}}&lt;/div&gt;&lt;/td&gt;
  &lt;td class=&quot;diff-marker&quot;&gt;&lt;/td&gt;
  &lt;td style=&quot;background-color: #f8f9fa; color: #202122; font-size: 88%; border-style: solid; border-width: 1px 1px 1px 4px; border-radius: 0.33em; border-color: #eaecf0; vertical-align: top; white-space: pre-wrap;&quot;&gt;&lt;div&gt;{{Related}}&lt;/div&gt;&lt;/td&gt;
&lt;/tr&gt;

&lt;!-- diff cache key mediawiki:diff:1.41:old-251:rev-289:wikidiff2=table:1.14.2:bc2a06be --&gt;
&lt;/table&gt;</summary>
		<author><name>Admin</name></author>
	</entry>
	<entry>
		<id>https://ohcnwiki.tellmey.fyi/index.php?title=TELEICU/Power_loss_runbook&amp;diff=251&amp;oldid=prev</id>
		<title>Admin: Create TELEICU power loss runbook (via create-page on MediaWiki MCP Server)</title>
		<link rel="alternate" type="text/html" href="https://ohcnwiki.tellmey.fyi/index.php?title=TELEICU/Power_loss_runbook&amp;diff=251&amp;oldid=prev"/>
		<updated>2026-07-06T02:54:06Z</updated>

		<summary type="html">&lt;p&gt;Create TELEICU power loss runbook (via create-page on MediaWiki MCP Server)&lt;/p&gt;
&lt;p&gt;&lt;b&gt;New page&lt;/b&gt;&lt;/p&gt;&lt;div&gt;{{Doc header&lt;br /&gt;
|type=runbook&lt;br /&gt;
|domain=teleicu&lt;br /&gt;
|title=Power loss runbook&lt;br /&gt;
|order=12&lt;br /&gt;
}}&lt;br /&gt;
&lt;br /&gt;
Procedure for handling a site power loss event.&lt;br /&gt;
&lt;br /&gt;
== Detection ==&lt;br /&gt;
&lt;br /&gt;
Node heartbeat stops. On-device agent (if still running on UPS) reports power loss classification. If UPS is also depleted, the node goes completely silent.&lt;br /&gt;
&lt;br /&gt;
== Immediate actions (first 10 min) ==&lt;br /&gt;
&lt;br /&gt;
# Confirm classification — check VictoriaMetrics for last recorded power metrics&lt;br /&gt;
# Notify hub admin assigned to the site per [[TELEICU/Incident management|Incident management]]&lt;br /&gt;
# If UPS runtime data is available (from site inventory), estimate remaining uptime&lt;br /&gt;
&lt;br /&gt;
== During outage ==&lt;br /&gt;
&lt;br /&gt;
* Node is offline. K3s control plane marks it as unreachable. etcd tolerates the absence.&lt;br /&gt;
* Workloads on that node will be rescheduled only if they have inter-pod anti-affinity and replicas elsewhere. By design, spoke workloads are typically singletons.&lt;br /&gt;
&lt;br /&gt;
== Recovery ==&lt;br /&gt;
&lt;br /&gt;
When power is restored:&lt;br /&gt;
&lt;br /&gt;
# Node boots automatically (BIOS set to &amp;quot;power on after AC loss&amp;quot;)&lt;br /&gt;
# K3s agent re-registers with the control plane&lt;br /&gt;
# Tailscale tunnel re-establishes&lt;br /&gt;
# Cloudflare tunnel service starts&lt;br /&gt;
# Middleware containers come up in order&lt;br /&gt;
# Monitoring agent reconnects and catches up on buffered metrics&lt;br /&gt;
# On-device agent reports &amp;quot;recovered from power loss&amp;quot;&lt;br /&gt;
&lt;br /&gt;
== Post-recovery verification ==&lt;br /&gt;
&lt;br /&gt;
- [ ] K3s node status: &amp;lt;code&amp;gt;kubectl get nodes&amp;lt;/code&amp;gt; shows Ready&lt;br /&gt;
- [ ] Middleware health endpoint returns 200&lt;br /&gt;
- [ ] Metrics flowing to VictoriaMetrics&lt;br /&gt;
- [ ] Hub admin acknowledges site is operational&lt;br /&gt;
&lt;br /&gt;
== Prevention ==&lt;br /&gt;
&lt;br /&gt;
* Site inventory should capture UPS capacity for each node (see site template)&lt;br /&gt;
* Consider solar + battery for high-priority sites with frequent power loss&lt;br /&gt;
* Graceful shutdown scripts on UPS trigger can be added via ansible or NixOS module&lt;br /&gt;